- Gas Safety (Installation and Use) Regulations 1998
- Regulation 36 requires an annual check on each relevant appliance and flue, a record kept for at least two years, and a copy given to the tenant within 28 days. The record is a finished certificate the moment it is saved, carrying the appliance by appliance safe to use status, the defects, the engineer's printed name and registration number, the issue date and the next check due date, with both signatures. Unibuild does not check the Gas Safe Register and does not email the record automatically.
- Retained UK F-Gas Regulation
- Operators of relevant equipment must have leak checks at prescribed intervals and keep records covering the quantity and type of gas, quantities added or recovered, who carried out the checks and the results. The platform holds all of that against the asset and prints a REFCOM presented log book. It does not derive your leak check frequency band from the carbon dioxide equivalent, and it does not chase an overdue check.
- SFG20
- FM contracts are routinely written to require maintenance in accordance with named SFG20 schedules and evidence that the specified tasks were carried out. Unibuild holds your own licensed schedule documents against each asset, with the PPM pattern and the completed service history. It is a document and reference store, not a live feed, and task level completion against SFG20 task references is not recorded.
- ACOP L8 and HSG274
- The duty holder must identify and assess risk, appoint a competent person, prepare a written scheme, implement and monitor it, and keep records of monitoring for at least five years. Unibuild carries the monitoring programme the scheme produces, dated, assigned and chased, with a thirty day forward warning. It does not author the risk assessment or the written scheme, and today the registers hold the due dates rather than the temperature readings themselves.
- BS 8558 and BS EN 806-4
- Disinfection is expected after a new installation, an extension, a repair where contamination may have occurred, or where a system has stood unused. The chlorination certificate names the standard worked to, records the contact time, and holds the before and after readings with the bacterial sample taken after flushing.
- Electricity at Work Regulations 1989, regulation 4(2)
- All systems shall be maintained, so far as is reasonably practicable, so as to prevent danger. The regulation sets an outcome, not a method: it says nothing about portable appliance testing, intervals or labels. The register is the evidence that a maintenance regime exists and is being followed, and the interval is yours to set from your own risk assessment.
- ISO 9001:2015, clause 7.1.5.2
- Measuring equipment must be calibrated at specified intervals, identified so its status can be determined, and safeguarded. Critically, where equipment is found unfit, the organisation must determine whether previous results were affected and take action. Unibuild identifies the instrument and holds its status and its certificate. It cannot today tell you which results a given instrument produced, which is the honest gap set out below.
- PUWER 1998
- Work equipment must be suitable, maintained in efficient working order and in good repair, and inspected where safety depends on installation or deterioration, with the inspection recorded. Every item is an individual record with a dated service history and, for portable electrical equipment, its full test history reachable by scanning the label on the item.